Analysis Dashboard
Amphenol DuraEV
|
DOE #2024-001
Accel Factor
2.8x
Arrhenius Model @ 30°C rise
Real-World Equiv.
9.4 Years
Based on duty cycle
Thermal Coverage
5%
Limited by 105°C cap
Test Protocol Logic
1. Baseline
LLCR (Dry Circuit), Insulation Resistance, Visual Inspection.
2. Accelerated Stress
Interspersed cycling
Loop 5x:
├─ Mechanical Cycles
├─ Thermal Soak
└─ Humidity
├─ Mechanical Cycles
├─ Thermal Soak
└─ Humidity
3. Final Analysis
LLCR < 15mΩ Delta, No base metal exposure.